No
|
Product
|
Quantity
|
Unit Price
|
Amount
|
Function
|
| 1 | TO SUPPLY LABOUR AND MATERIALS TO INSTALL | 1.00 | 5,200.00 | 5,200.00 | Edit | Delete | | | EXHAUST AIR FOR KITCHEN
FABRICATE EXHAUST DUCT 800X500 , MATERIAL USED; GI , C/W 1 NOS FOUR WAY GRILL ,FLEXIBLE AND NECESSARY ACCESSRIES
*does not include kitchen hood.
| | 2 | TO SUPPLY AND INSTALL 125 IN-LINE FAN | 1.00 | 1,800.00 | 1,800.00 | Edit | Delete | | | TO SUPPLY LABOUR AND FABRICATE MAIN DUCT 150X150 ,MATERIAL USED; PU FOAM. INCLUDE 1NOS EXHAUST AIR GRILL.
FOR TEAF1-1
| | 3 | TO SUPPLY LABOUR AND MATERIALS TO INSTALL KFAD | 1.00 | 4,200.00 | 4,200.00 | Edit | Delete | | | TO SUPPLY LABOUR AND FABRICATE MAIN DUCT 600X400 ,MATERIAL USED; GI. INCLUDE 1NOS EXHAUST AIR GRILL.
FOR LEVEL1
| | 4 | TO SUPPLY AND INSTALL FRESH AIR (AC FAD ) LEVEL1 | 1.00 | 2,800.00 | 2,800.00 | Edit | Delete | | | SUPPLY AND INSTALL IN-LINE FAN
FABRICATE MAIN DUCT 150X150, MATERIAL USED; PU FOAM,C/W FOUR WAY GRILL FLEXIBLE AND NECESSARY ACCESSRIES
FOR LEVEL 1 4UNIT CASSETTE .
| | 5 | TO SUPPLY AND INSTALL FRESH AIR (AC FAD ) LEVEL2 | 1.00 | 2,800.00 | 2,800.00 | Edit | Delete | | | SUPPLY AND INSTALL IN-LINE FAN
FABRICATE MAIN DUCT 150X150, MATERIAL USED; PU FOAM,C/W FOUR WAY GRILL FLEXIBLE AND NECESSARY ACCESSRIES
FOR LEVEL 2- 4UNIT CASSETTE .
| | 6 | TO SUPPLY AND INSTALL FRESH AIR (AC FAD ) LEVEL3 | 1.00 | 2,800.00 | 2,800.00 | Edit | Delete | | | SUPPLY AND INSTALL IN-LINE FAN
FABRICATE MAIN DUCT 150X150, MATERIAL USED; PU FOAM,C/W FOUR WAY GRILL FLEXIBLE AND NECESSARY ACCESSRIES
FOR LEVEL 3- 4UNIT CASSETTE .
| | 7 | TO SUPPLY AND INSTALL FRESH AIR (AC FAD ) LEVEL4 | 1.00 | 1,950.00 | 1,950.00 | Edit | Delete | | | SUPPLY AND INSTALL IN-LINE FAN
FABRICATE MAIN DUCT 150X150, MATERIAL USED; PU FOAM,C/W FOUR WAY GRILL FLEXIBLE AND NECESSARY ACCESSRIES
FOR LEVEL 4- 2UNIT CASSETTE .
| | 8 | TO SUPPLY AND INSTALL FRESH AIR (AC FAD ) LEVEL5 | 1.00 | 1,950.00 | 1,950.00 | Edit | Delete | | | SUPPLY AND INSTALL IN-LINE FAN
FABRICATE MAIN DUCT 150X150, MATERIAL USED; PU FOAM,C/W FOUR WAY GRILL FLEXIBLE AND NECESSARY ACCESSRIES
FOR LEVEL 5- 2UNIT CASSETTE .
| | 9 | REMARKS | | | | Edit | Delete | | | **EXCLUDE SUBMISSION AND **CRANE BOOKING .
**EXCLUDE FRESH AIR (AC FAD ) FOR FCU L 1/1/FCU L-1/2/FCU L-1/3
1) 50% DEPOSIT TO ORDER AIRCON AND CONFIRM JOB.
2) 30% PROGRESSIVE CLAIM WHEN AIRCON ARRIVE.
3) 20%FULL PAYMENT UPON JOB COMPLETED.
4) EXCLUSION: WORKS NOT STATED ABOVE. | | Total | 8.00 | | 23,500.00 |
|
10 |
|
|
|
|
|
|
|
|
|
|