						No
					 | 
					
						Product
					 | 
					
						Quantity
					 | 
					
						Unit Price
					 | 
					
						Amount
					 | 
					
						Function
					 | 
				 
				| 1 | TO SUPPLY AIRCON LABOUR AND MATERIALS TO INSTALL MITSUBISHI ELECTIRC VRF | 1.00 | 32,800.00 | 32,800.00 |   Edit |   Delete |  |   | 1ST STOREY
 MODEL : PUCY-P400YKD 16HP X1
 MODEL : PKFY-P50VLM-E.TH(W) - FCU1-1 HOME GYM - ( WALL MOUNTED ) 
 MODEL : PKFY-P50VLM-E.TH(W) - FCU 1-2 HOME GYM  - ( WALL MOUNTED )
 MODEL : PKFY-P63VKM-E(W) - FCU 1-3 GUEST ROOM - ( WALL MOUNTED )
 MODEL : PEFY-P80VMA-E(W) - FCU 1-4 LIVING ROOM - ( CEILING DUCTED )
 MODEL : PKFY-P25VLM-E.TH(W) - FCU 1-5 MAID ROOM - ( WALL MOUNTED )
 2ND STOREY
 MODEL : PKFY-P63VKM-E(W) - FCU 1-6 BEDROOM 1 - ( WALL MOUNTED )
 MODEL : PKFY-P63VKM-E(W) - FCU 1-7 BEDROOM 2 - ( WALL MOUNTED )
 
  |  | 2 | TO SUPPLY AIRCON LABOUR AND MATERIALS TO INSTALL MITSUBISHI ELECTIRC VRF | 1.00 | 29,900.00 | 29,900.00 |   Edit |   Delete |  |   | 1ST STOREY
  MODEL : PUCY-P400YKD 16HP X1
 MODEL : PKFY-P50VLM-E.TH(W) - FCU 2-1 HOME ENTERTAINMENT ROOM - ( WALL MOUNTED ) 
 MODEL : PKFY-P50VLM-E.TH(W) - FCU 2-2 HOME ENTERTAINMENT ROOM - ( WALL MOUNTED )
 MODEL : PEFY-P80VMA-E(W) - FCU 2-3 LIVING ROOM - ( CEILING DUCTED )
 MODEL : PEFY-P125VMA-E(W) - FCU 2-4 LIVING ROOM - ( CEILING DUCTED )
 2ND STOREY
 MODEL : PKFY-P63VKM-E(W) - FCU 2-5 BEDROOM 3 - ( WALL MOUNTED )
 MODEL : PKFY-P50VLM-E.TH(W) - FCU 2-6 BEDROOM 4 - ( WALL MOUNTED )
 
  |  | 3 | TO SUPPLY AIRCON LABOUR AND MATERIALS TO INSTALL MITSUBISHI ELECTIRC VRF | 1.00 | 26,800.00 | 26,800.00 |   Edit |   Delete |  |   | 1ST STOREY
 MODEL : PUCY-P400YKD
 MODEL : PEFY-P125VMA-E(W) - FCU 3-1 DINING ROOM - ( CEILING DUCTED )
 MODEL : PKFY-P63VKM-E(W) - FCU 3-2 WET KITCHEN - ( WALL MOUNTED )
 2ND STOREY
 MODEL : PKFY-P50VLM-E.TH(W) - FCU 3-3 BEDROOM 5 - ( WALL MOUNTED )
 MODEL : PKFY-P63VKM-E(W) - FCU 3-4 BEDROOM 6 - ( WALL MOUNTED )
 MODEL : PEFY-P125VMA-E(W) - FCU 3-5 MASTER BEDROOM - ( CEILING DUCTED )
 
 
 **INCLUDE INSULATION MAIN PIPE 1" THK (GAS);1/2" THK (LIQUID); TO FCU 3/4" THK;
 WATER PIPE 16MM-25MM; CABLE TRAY AND ALL NECESSARY PARTS.
 **INCLUDE CONCEAL
 TESTING $ COMMISSIONING APPLIED.
 
 *WARRANTY FOR NEW AIRCON
 *1 YEAR SPARE PARTS
 *5 YEARS COMPRESSOR
 
 **CRANE BOOKING (IF ANY) $1900/1DEY
 **EXCLUDE AIRCON BRACKET
  |  | 4 | DUCT WORK FOR CEILING DUCTED PEFY-P125VMA | 3.00 | 4,200.00 | 12,600.00 |   Edit |   Delete |  |   | TO SUPPLY LABOUR AND FABRICATE MAIN DUCT AND MATERIAL USED; PU FOAM.
 INCLUDE FILTER AND WATER TARY AND ALL NECESSARY PARTS.
 
  |  | 5 | 	DUCT WORK FOR CEILING DUCTED PEFY-P80VMA | 2.00 | 3,900.00 | 7,800.00 |   Edit |   Delete |  |   | TO SUPPLY LABOUR AND FABRICATE MAIN DUCT AND MATERIAL USED; PU FOAM.
 INCLUDE FILTER AND WATER TARY AND ALL NECESSARY PARTS.
 
  |  | 6 | DRAWING AND SUBMISSION | 1.00 | 1,800.00 | 1,800.00 |   Edit |   Delete |  | 7 | 	TO SUPPLY AND INSTALL EXHAUST AIR  | 1.00 | 1,400.00 | 1,400.00 |   Edit |   Delete |  |   | 200X200 EAD /210CMH 
 FABRICATE MAIN DUCT , MATERIAL USED; PU FOAM,C/W FOUR WAY GRILL FLEXIBLE AND NECESSARY ACCESSRIES
 
  |  							
								| 
									8								 | 
								
									
																		  
									 	
								 | 
								
																	 | 
								
																	 | 
								
								 | 
							 							
							
								| 
								 | 
								
																	 | 
							 
							
								| 
																		  
																	 | 
							 	
				| 9 | TO SUPPLY AND INSTALL FRESH AIR  | 1.00 | 1,400.00 | 1,400.00 |   Edit |   Delete |  |   | 200X200 FAL /190CMH 
 FABRICATE MAIN DUCT , MATERIAL USED; PU FOAM,C/W FOUR WAY GRILL FLEXIBLE AND NECESSARY ACCESSRIES
 
 REMARKS
 1)30% DEPOSIT AFTER PIPE LAYING AND INSTALL.
 2)50% SECOND PAYMENT UPON AIRCON ARRIVAL BEFORE INSTALLATION
 3)20% FULL PAYMENT UPON JOB COMPLETION.
 4) DELIVERY: EX-STOCK PRIOR TO SALE, OTHERWISE 1 TO 3 MONTHS FROM DATE OF PURCHASE ORDER RECEIVED. |  | Total | 11.00 |   | 114,500.00 |  			 
		 |